Commercial lighting · Case study
Brighter courts.
Lower energy use.
A carefully planned LED lighting upgrade for Altona Sports Centre, delivering a measured improvement in brightness and substantial estimated electricity savings.
Altona Meadows, Victoria · Completed 1 October 2026

brighter on average
Measured before and after with a lux meter.
less lighting energy
Estimated reduction across the lighting upgrade.
estimated annual savings
Electricity savings, ex. GST, at 2,000 hours a year.
estimated simple payback
Just over one year after the VEU subsidy.
The challenge
Better lighting for a busy sports centre.
Altona Sports Centre needed to address three connected problems: poor brightness, high electricity costs and the maintenance demands of ageing fluorescent lighting.
The upgrade covered all basketball courts and the function room at 1 Andrew Park Drive, Altona Meadows. The aim was to improve the lighting while reducing its energy demand, with installation completed during a short window when the courts were not in use.
The upgrade
A complete lighting refresh.
Court high bays
Linear fluorescent high bays replaced with circular LED high bays.
Court batten fittings
Fluorescent tube fittings upgraded to LED battens.
Function-room battens
Fluorescent tube fittings upgraded to LED battens.
On site
The fittings tell the story.


These are genuine project photographs. Automatic phone-camera exposure and different viewpoints mean they are not a controlled comparison of brightness. The 58% improvement is based on before-and-after lux-meter measurements.
Installation
Eight metres up.
Care at floor level.
Protecting the basketball court surfaces was central to the plan. Standard scissor lifts were unsuitable for the flooring, so the team used Dino aerial platforms to reach the eight-metre ceiling.
The access hire company visited the site to assess the equipment’s suitability for the courts. Protective mats were placed beneath the wheels when moving the platforms around, with particular care taken throughout the installation.
The work was completed in two and a half days, within the centre’s three-day window when the courts were not in use.


Watch the project
See the upgrade in action.
A short look at the Altona Sports Centre lighting project, from installation to the finished courts.
Watch on YouTubeVEU support & payback
A smaller upfront cost.
A faster return.
The Victorian Energy Upgrades subsidy reduced the customer’s upfront project cost by approximately 58%.
≈13 monthsEstimated simple payback — just over one year.
| Project cost before subsidy | $39,176 |
|---|---|
| VEU subsidy | −$22,800 |
| Customer out-of-pocket cost | $16,376 |
| Estimated annual electricity savings | $14,700 |
Simple payback: $16,376 ÷ $14,700 ≈ 1.11 years. This compares the customer’s cost after subsidy with estimated annual electricity savings.
How the results were assessed
Measured brightness. Estimated savings.
Brightness was measured before and after installation using a lux meter, with an average improvement of 58%. Individual lux readings are not published.
The estimated 88% reduction relates to lighting electricity consumption, rather than the centre’s total electricity use. The calculation covers the high bays and batten upgrades and includes the ballast load of the old fluorescent fittings.
Annual electricity savings of approximately $14,700 ex. GST are based on 2,000 operating hours per year. Actual savings and payback depend on operating hours and electricity tariffs.