Commercial lighting · Case study

Brighter courts.
Lower energy use.

A carefully planned LED lighting upgrade for Altona Sports Centre, delivering a measured improvement in brightness and substantial estimated electricity savings.

Altona Meadows, Victoria · Completed 1 October 2026

Circular LED high bays illuminating the basketball courts at Altona Sports Centre after the upgrade
Altona Sports Centre · After the upgrade
58%

brighter on average

Measured before and after with a lux meter.

88%

less lighting energy

Estimated reduction across the lighting upgrade.

$14,700

estimated annual savings

Electricity savings, ex. GST, at 2,000 hours a year.

≈13 months

estimated simple payback

Just over one year after the VEU subsidy.

Better lighting for a busy sports centre.

Altona Sports Centre needed to address three connected problems: poor brightness, high electricity costs and the maintenance demands of ageing fluorescent lighting.

The upgrade covered all basketball courts and the function room at 1 Andrew Park Drive, Altona Meadows. The aim was to improve the lighting while reducing its energy demand, with installation completed during a short window when the courts were not in use.

A complete lighting refresh.

100

Court high bays

Linear fluorescent high bays replaced with circular LED high bays.

25

Court batten fittings

Fluorescent tube fittings upgraded to LED battens.

12

Function-room battens

Fluorescent tube fittings upgraded to LED battens.

Eight metres up.
Care at floor level.

Protecting the basketball court surfaces was central to the plan. Standard scissor lifts were unsuitable for the flooring, so the team used Dino aerial platforms to reach the eight-metre ceiling.

The access hire company visited the site to assess the equipment’s suitability for the courts. Protective mats were placed beneath the wheels when moving the platforms around, with particular care taken throughout the installation.

The work was completed in two and a half days, within the centre’s three-day window when the courts were not in use.

Dino aerial platform reaching the sports centre ceiling during lighting installation, with protective mats at floor level
Specialist access for the eight-metre ceiling.
Dino aerial platform positioned on protective coverings on the basketball court
Careful preparation to protect the court surfaces.

See the upgrade in action.

A short look at the Altona Sports Centre lighting project, from installation to the finished courts.

Watch on YouTube

A smaller upfront cost.
A faster return.

The Victorian Energy Upgrades subsidy reduced the customer’s upfront project cost by approximately 58%.

≈13 monthsEstimated simple payback — just over one year.

Project costs · All figures ex. GST
Project cost before subsidy$39,176
VEU subsidy−$22,800
Customer out-of-pocket cost$16,376
Estimated annual electricity savings$14,700

Simple payback: $16,376 ÷ $14,700 ≈ 1.11 years. This compares the customer’s cost after subsidy with estimated annual electricity savings.

Measured brightness. Estimated savings.

Brightness was measured before and after installation using a lux meter, with an average improvement of 58%. Individual lux readings are not published.

The estimated 88% reduction relates to lighting electricity consumption, rather than the centre’s total electricity use. The calculation covers the high bays and batten upgrades and includes the ballast load of the old fluorescent fittings.

Annual electricity savings of approximately $14,700 ex. GST are based on 2,000 operating hours per year. Actual savings and payback depend on operating hours and electricity tariffs.

Could your lighting work harder for you?

We assess your current fittings, lighting needs and installation requirements, then explain the costs and any applicable VEU subsidy.

Discuss your lighting project Explore commercial lighting